  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
32
7. Press the ENTER key
M I N S E T P O I N T
S E T P T : 0 . 0 A
8. Use the UP and DOWN keys to adjust the current setpoint
M I N S E T P O I N T
S E T P T : 2 . 0 A
9. Press the ENTER key to accept the calibration value.
P U L S A G U A R D
C A L I B R A T E D
10. PulsaGuard Pump Protection is now calibrated and enabled.
8.5 Display Contrast Adjustment
Should adjustment of the contrast level of the display become necessary, use the following procedure while
in the normal operating mode.
To increase contrast, press and hold at the same time.
To decrease contrast, press and hold at the same time.