7.6 Motor Removal & Reinstallation
1. Disconnect the power source to the drive motor.
2. Disconnect the motor wiring from the motor.
3. Remove the four bolts retaining the motor to the motor adaptor.
Lift the motor upwards away from the
pump.
4. Apply an anti-seize paste or lubricant to all bolts, setscrews, and keys
before reassembling..
5. Reinstall the motor in the reverse from removal.
6. Insert and tighten the four bolts removed in step 3.
7. Reconnect the motor wiring to the motor.
8. Connect power to the drive motor.
Motor rotation must be wired for CW rotation,
as viewed from the top of the motor, as noted
by the arrow on the top of the pump housing.
Figure 15, motor
mounting