To set up Pressure:
1. Complete re-assembly of the diaphragm, reagent head, and external components if they were
taken apart. Ensure that reagent head and tie-bar bolts are tightened according to the
appropriate torque specifications
2. Remove the pressure gauge from the housing body and replace it with a straight tubing
adaptor fitting. This will be referred to in this document as the “outlet side”
Figure 6 – fitting for priming “outlet side”
3. Remove the plug from the inlet side needle valve on the front of the reagent head, and install
a hose adaptor fitting. This will be referred to in this document as the “inlet side”.
Figure 7 – “inlet side”
fitting